| Inspection |
| 1. |
Turn ignition switch OFF. |
| 2. |
Remove the battery and battery tray.
(Refer to Engine Electrical System - "Battery") |
| 3. |
Disconnect the solenoid valve connector (A).
|
| 4. |
Measure the resistance between power terminal (5) and signal terminal (17).
|
| Replacement |
If a solenoid valve of VFS type needs to be replaced, the
valve body assembly should be replaced and the oil pressure should be
adjusted. If the solenoid valve is replaced individually, it is not
possible to adjust the oil pressure without additional equipment, and if
the oil pressure adjustment procedure is not performed, a shift shock
or delay may occur. |
| 1. |
Replace the valve body assembly.
(Refer to Hydraulic System - "Valve Body") |
Circuit Diagram
Specification ItemSpecificationControl type ON/OFFCurrent value (mA)5.0 Coil resistance(Ω)10 ~ 11
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.
Replacement 1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery/ recycling/ charging station. 3. When the engine is cool, drain the engine coolant from the radiator. 4. Remove the expansion valve cover (A).