| Description |

Removal When replacing the TCM, the vehicle equipped with the immobilizer must be performed procedure as below. [In the case of installing used TCM] 1) Perform "TCM Neutral mode" procedure with GDS.
Specifications ▷ Type: Negative Thermal Coefficient(NTC) Type Temp.[(°C)°F]Resistance (kΩ)(-40)-4048.1(-20)-4.015.6(0)32.05.88(20)68.02.51(40)104.
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the glove box housing. (Refer to Body - "Glove Box Housing") 3. Remove the SVM unit (B) after disconnecting the connectors (A) and mounting bolts. Installation 1. Install the SVM unit.
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. Specification FanMotor VoltageManualFirst speed3.8 ±0.5VSecond speed5.