Kia Cadenza YG: Air Conditioning System / A/C Pressure Transducer Repair procedures

Inspection
1.
Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals.

2.
Inspect the voltage value whether it is sufficient to be regular value or not.


Voltage = 0.00878835 * Pressure + 0.37081095 [PSIA]

3.
If the measured voltage value is not specification, replace the A/C pressure transducer.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Recover the refrigerant with a recovery/charging station.
3.
Disconnect the A/C pressure transducer connector (A).

4.
Remove the A/C pressure transducer (B).

Tightening torque:
10~12N.m (1.0~1.2kgf.m, 7.4~8.8 lbf.ft)

   
Take care that liquid & suction pipe are not bent.
5.
Installation is the reverse order of removal.

    Description A/C pressure transducer convert the pressure value of high pressure line into voltage value after measure it. By converted voltage value, engine ECU controls cooling fan by operating it high speed or low speed.

    Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator freezing by excessive cooling.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Components and Components Location

    C

    Kia Cadenza YG 2016-2021 Service Manual: Auto defoging sensor Repair procedures

    Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal23Auto defog sensor OPEN24Auto defog sensor SHORT43Defog door potentiometer OPEN/SHORT44Defog door potentiometer * Diagnostic procedure refer to DTC code.

    Categories

     
    Copyright © 2025 www.kcadenzavg.com - 0.0172