Kia Cadenza: Engine Control System / Manifold Absolute Pressure Sensor (MAPS) Description and Operation

Kia Cadenza YG 2016-2025 Service Manual / Engine Control / Fuel System / Engine Control System / Manifold Absolute Pressure Sensor (MAPS) Description and Operation

Description
Manifold Absolute Pressure Sensor (MAPS) is a speed-density type sensor and is installed on the surge tank. It senses absolute pressure of the surge tank and transfers the analog signal proportional to the pressure to the ECM.
By using this signal, the ECM calculates the intake air quantity and engine speed.
The MAPS consists of a piezo-electric element and a hybrid IC amplifying the element output signal. The element is silicon diaphragm type and adapts pressure sensitive variable resistor effect of semi-conductor.
Because 100% vacuum and the manifold pressure apply to both sides of the sensor respectively, this sensor can output analog signal by using the silicon variation proportional to pressure change.

Intake Air Temperature Sensor (IATS) Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the IATS connector. 3. Measure resistance between the IATS terminals 3 and 4. 4. Check that the resistance is within the speci ...

Manifold Absolute Pressure Sensor (MAPS) Specifications
Specification Pressure [kPa (kgf/cm², psi)]Output Voltage (V)20.0 (0.20, 2.90)0.7946.66 (0.47, 6.77)1.84101.32 (1.03, 14.7)4.0 ...

Other information:

Kia Cadenza YG 2016-2025 Service Manual: Windshield Deicer Repair procedures


Inspection 1. Remove the cowl top cover. (Refer to the wiper) 2. Disconnect the windshield deicer connector (A) from the wiper motor linkage. 3. Check for continuity between the terminals of deicer lines. 4. Turn the ignition switch ON and the windshield deicer switch ON, then meas ...

Kia Cadenza YG 2016-2025 Service Manual: Audio Remote Control Repair procedures


Inspection [Steering Remote Control Switch] 1. Check the audio remote control switch for resistance between terminals in each switch position. [Audio (LH)] SwitchConnectorterminalResistance(±5%)Seek up2-7430 ΩSeek down2-71.1 kΩMode2-72.11 kΩMute2-73.11 kΩVolume up2-74.61 kΩVolume ...

Copyright © www.kcadenzavg.com 2017-2025