Kia Cadenza YG: Emission Control System / Specifications
Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
| Specification
|
Coil Resistance (Ω)
| 22.0 ~ 26.0 [20°C(68°F)]
|
Fuel Tank Pressure Sensor (FTPS)
▷ Type: Piezo-Resistive Pressure Sensor
▷ Specification
Pressure (kPa)
| Output Voltage (V)
|
-6.67
| 0.5
|
0
| 2.5
|
+6.67
| 4.5
|
Canister Close Valve (CCV)
▷ Specification
Item
| Specification
|
Coil Resistance (Ω)
| 19.8 ~ 21.8 [20°C(68°F)]
|
Item
| kgf.m
| N.m
| lb-ft
|
Positive Crankcase Ventilation (PCV) Valve installation
| 0.8 ~ 1.2
| 7.8 ~ 11.8
| 5.8 ~ 8.7
|
Canister installation bolt
| 0.4 ~ 0.6
| 3.9 ~ 5.9
| 2.9 ~ 4.3
|
Canister protector installation bolt
| 0.9 ~ 1.4
| 8.8 ~ 13.7
| 6.5 ~ 10.1
|
ORVR installation bolt
| 0.2 ~ 0.3
| 1.9 ~ 2.9
| 1.4 ~ 2.1
|
Components Location
1. PCV Valve2. Canister3. Purge Control Solenoid Valve (PCSV)4. Fuel Tank Pressure Sensor (FTPS)5. Canister Close Valve (CCV)6.
Other information:
C
Instructions
When Handling Refrigerant
1.
R-134a liquid refrigerant is highly volatile. A drop on the
skin of your hand could result in localized frostbite. When handling the
refrigerant, be sure to wear gloves.
2.
It is standard practice to wear goggles or glasses to protect
your eyes, and gloves to protect your hands.