Kia Cadenza YG: Emission Control System / Specifications
Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
| Specification
|
Coil Resistance (Ω)
| 22.0 ~ 26.0 [20°C(68°F)]
|
Fuel Tank Pressure Sensor (FTPS)
▷ Type: Piezo-Resistive Pressure Sensor
▷ Specification
Pressure (kPa)
| Output Voltage (V)
|
-6.67
| 0.5
|
0
| 2.5
|
+6.67
| 4.5
|
Canister Close Valve (CCV)
▷ Specification
Item
| Specification
|
Coil Resistance (Ω)
| 19.8 ~ 21.8 [20°C(68°F)]
|
Item
| kgf.m
| N.m
| lb-ft
|
Positive Crankcase Ventilation (PCV) Valve installation
| 0.8 ~ 1.2
| 7.8 ~ 11.8
| 5.8 ~ 8.7
|
Canister installation bolt
| 0.4 ~ 0.6
| 3.9 ~ 5.9
| 2.9 ~ 4.3
|
Canister protector installation bolt
| 0.9 ~ 1.4
| 8.8 ~ 13.7
| 6.5 ~ 10.1
|
ORVR installation bolt
| 0.2 ~ 0.3
| 1.9 ~ 2.9
| 1.4 ~ 2.1
|
Components Location
1. PCV Valve2. Canister3. Purge Control Solenoid Valve (PCSV)4. Fuel Tank Pressure Sensor (FTPS)5. Canister Close Valve (CCV)6.
Other information:
Inspection
1.
Ignition "ON"
2.
Manually operate the control switch and measure the voltage of blower motor.
3.
Select the control switch to raise voltage until high speed.
Specification
FanMotor VoltageManualFirst speed3.8 ±0.5VSecond speed5.
C