Kia Cadenza: Engine Control System / Canister Close Valve (CCV) Repair procedures

Kia Cadenza YG 2016-2025 Service Manual / Engine Control / Fuel System / Engine Control System / Canister Close Valve (CCV) Repair procedures

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the CCV connector.
3.
Measure resistance between the CCV terminal 1 and 2.
4.
Check that the resistance is within the specification.

Specification: Refer to "Specification"

5.
Disconnect the vapor hose connected with the canister from the CCV.
6.
Connect a vacuum pump to the nipple.
7.
Ground the CCV control line and apply battery voltage to the CCV power supply line.
8.
Apply vacuum and check the valve operation.

Specification: Vacuum maintained

Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Lift the vehicle.
3.
Disconnect the canister close valve connector (A).
4.
Disconnect the ventilation hose (B) from the fuel tank air filter and canister close valve.
5.
Remove the fuel tank air filter assembly after removing bolts (C).

6.
Release the lever (A), and then separate the canister close valve (B) from the fuel tank air filter (C) after rotating it in the direction of the arrow in the figure.

Installation
Install the component with the specified torques.
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
1.
Install in the reverse order of removal.
Canister Close Valve (CCV) Schematic Diagrams
Circuit Diagram ...

Fuel Delivery System
...

Other information:

Kia Cadenza YG 2016-2025 Service Manual: Description and Operation


Description Automatic transaxle system relies on various measurement data to determine the current control status and extrapolate the necessary compensation values. These values are used to control the actuators and achieve the desired control output. If a problem with the drivetrain, inc ...

Kia Cadenza YG 2016-2025 Service Manual: Blower Motor Repair procedures


Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation. 3. If the problem is corrected, replace the blower motor. Replacement 1. Dis ...

Copyright © www.kcadenzavg.com 2017-2025