| Inspection |
| 1. |
Open the fuel filler door and remove the fuel filler door release actuator (A) after loosening the mounting bolts.
|
| 2. |
Remove the trunk room left side trim.
(Refer to Body - "Interior Trim") |
| 3. |
Disconnect the release actuator connector (A).
|
| 4. |
Check for continuity between terminal No.1 and No.2.
If there is no continuity, replace the fuel filler door opener. |
Component Location 1. Fuel filler door open switch2. Fuel filler door release actuator
Inspection 1. Open the junction box fuse cover. 2. Insert the hand to the junction box fuse cover hole and remove the crash pad side switch assembly (A) by pushing it.
Replacement 1. Discharge refrigerant from refrigeration system. 2. Replace faulty tube or hose. Cap the open fittings immediately to keep moisture or dirt out of the system. 3. Tighten joint of bolt or nut to specified torque.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.