| Inspection |
| 1. |
Ignition "ON" |
| 2. |
Manually operate the control switch and measure the voltage of blower motor. |
| 3. |
Select the control switch to raise voltage until high speed.
Specification
*AUTO COOLING: Auto speed (4.5V~B+)
*AUTO HEATING: Auto speed (4.5V~11.0V) |
| 4. |
If the measured voltage is not specification, substitute with a known-good power mosfet and check for proper operation. |
| 5. |
If the problem is corrected, replace the power mosfet. |
| Replacement |
| 1. |
Disconnect the negative (-) battery terminal. |
| 2. |
Remove the crash pad lower cover (A) and then disconnect the connector (B).
|
| 3. |
Remove the shower duct(A).
|
| 4. |
Disconnect the power mosfet connector (A) and then remove the power mosfet (B) after loosening the mounting screws.
|
| 5. |
Installation is the reverse order of removal. |
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
Inspection 1. Measure terminal - to - terminal resistance of blower resistor. 2. If measure resistance isnot within specification, the blower resistor must be replaced.
Specification ItemSpecificationUltrasonic sensorVoltage ratingDC 12 VDetecting range30 cm ~ 120 cmOperation voltageDC 9 ~ 16 VOperation currentMAX 300 mAOperation temperature-30°C ~ +80°C (-22°C ~ +176°C)Operation frequency48 ± 5 KHzEffective operating velocity10 KPH (6.
Replacement 1. Remove the condenser, and then remove the bottom cap (B) with L wrench (A) from the condenser. Tightening torque : 9.8~14.7N.m (1.0~1.5kgf.m, 7.2~10.8 lb-ft) 2. Remove the desiccant (A) from condenser using a long nose plier.