Kia Cadenza YG: Blower / Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Remove the shower duct (A).

4.
Disconnect the of the blower motor connector (A).
5.
Remove the blower motor (B) by pulling it after rotating 90° in a counter clock wise direction.

6.
Installation is the reverse order of removal.

    Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit.(Refer to HA group – heater unit). 3. Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.

    Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Description and Operation

    Description System Operation Typically, lane departure warning is activated at a speed over 70 KPH, but suppressed in case of unintentional lane departure when driver do not operate turn signal. System Operation Conditions 1. User Conditions (1) When unintended lane departure is occured, warnings are generated.

    Kia Cadenza YG 2016-2021 Service Manual: Troubleshooting

    Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor. Use the table below to help you find the cause of the problem.

    Categories

     
    Copyright © 2026 www.kcadenzavg.com - 0.0212