Kia Cadenza YG: Blower / Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Remove the shower duct (A).

4.
Disconnect the of the blower motor connector (A).
5.
Remove the blower motor (B) by pulling it after rotating 90° in a counter clock wise direction.

6.
Installation is the reverse order of removal.

    Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit.(Refer to HA group – heater unit). 3. Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.

    Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Description and Operation

    Description BSD is a system that uses two magnetic wave radar sensors attached on the rear bumper to measure the distance from the following vehicles and provides the sensing and (visual and auditory) alarm of any vehicle coming into the blind spot.

    Kia Cadenza YG 2016-2021 Service Manual: Troubleshooting

    Troubleshooting Examples of False-Alarm Occurrence from system characteristics (It’s not a problem) – Characteristics of EM Wave : EM Waves are reflected against all material and especially metal very well. Reflections of EM Waves are varies with the shape of object.