Kia Cadenza YG: Blower / Blower Unit Repair procedures

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater and blower unit.(Refer to HA group – heater unit).
3.
Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.

   
Make sure that there is no air leaking out of the blower and duct joints.
4.
Installation is the reverse order of removal.

    Component Location Components 1. Duct Seal2. Duct Case3. Inlet Door4. Intake Actuator5. Inlet Duct Case (A)6. Climate control air filter7. Cluster Ionizer8.

    Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Compressor Repair procedures

    Removal 1. If the compressor is marginally operable, run the engine at idle speed, and let the air conditioning work for a few minutes, then shut the engine off. 2. Disconnect the negative cable from the battery. 3. Recover the refrigerant with a recovery/charging station.

    Kia Cadenza YG 2016-2021 Service Manual: Cluster ionizer Description and Operation

    Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.