| Specifications |
| Items | Specification |
| Rated voltage | DC 12V |
| Operating voltage | 9V ~ 16V |
| Operating speed | 15km/h ~ 250km/h |
| Sensible distance | 70m (Sedan) |
| Curvature radius | Start : More than 100m Stop : Less than 70m |
| Frequency | 24 GHz |
| Numbers | 2EA (Master 1EA, Slave 1EA) |
Components 1. Blind Spot Detection (BSD) Unit2. BSD switch 3. BSD warning lamp (Built in the outside mirror)
Inspection 1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7. Verify that the temperature control actuator operates to the cool position when connecting in the rev
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.