Kia Cadenza: Automatic Transaxle Control System / SS-B Solenoid Valve(ON/OFF) Repair procedures
1.
Turn ignition switch OFF.
2.
Remove the battery and battery tray.
(Refer to Engine Electrical System - "Battery")
3.
Disconnect the solenoid valve connector (A).
4.
Measure the resistance between power terminal (5) and signal terminal (12).
Specification : 10.0 ~ 11.0 Ω
1.
Remove the under cover.
(Refer to Engine Mechanical System - "Engine Room Under Cover")
2.
Remove the ATF drain plug (A), allow the fluid to drain out and then reinstall the drain plug.
Tightening torque:
33.3 ~ 43.1 N.m (3.4 ~ 4.4 kgf.m, 24.6 ~ 31.8 lb-ft)
The existing ATF drain plug gasket must be replaced with new one. (Do not reuse it.)
3.
Remove the battery and battery tray.
(Refer to Engine Electrical System - "Battery")
4.
Remove the wiring bracket (A) and the air breather hose (B).
Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
5.
Lift the vehicle after loosening valve body cover upper bolts.
6.
Remove the valve body cover (A) by loosening bolts.
Tightening torque:
11.8 ~ 13.7 N.m (1.2 ~ 1.4 kgf.m, 8.7 ~ 10.1 lb-ft)
7.
Remove the solenoid valve harness (A) and oil temperature sensor (B) after removing the bolts.
Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
8.
Remove solenoid valve support bracket (A).
Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)
9.
Remove the SS-B solenoid valve (A).
1.
Install in the reverse order of removal.
•
The existing solenoid valve O-ring (A) must be replaced with new one. (Do not reuse it.)
•
The existing valve body cover gasket (A) must be replaced with new one. (Do not reuse it.)
•
Refill the automatic transaxle with fluid.
(Refer to Hydraulic System - "Fluid")
•
Confirm that there is no fluid leakage on connections after repairing.
Description
Inhibitor Switch monitors the lever''s position(P, R, N, D) and is used to control gear setting signals. ...
Other information:
Components
1. Oil cover2. Oil cover gasket3. Oil pressure switch
...
The mode selection button controls
the direction of the air flow through
the ventilation system.
The air flow outlet port is converted
as follows:
Air flow is directed toward the upper
body and face. Additionally, each
outlet can be controlled to direct the
air discharged from ...