Kia Cadenza YG: Fuel Filler Door / Fuel Filler Door Open Switch Repair procedures

Kia Cadenza YG 2016-2021 Service Manual / Body Electrical System / Fuel Filler Door / Fuel Filler Door Open Switch Repair procedures

Inspection
1.
Open the junction box fuse cover.
2.
Insert the hand to the junction box fuse cover hole and remove the crash pad side switch assembly (A) by pushing it.
   
Put on gloves to protect your hands.

3.
Disconnect the switch connector.
4.
Check for continuity between the terminal No.4 and No.5.
If there is no continuity, replace the fuel filler door open switch.

    Inspection 1. Open the fuel filler door and remove the fuel filler door release actuator (A) after loosening the mounting bolts. 2. Remove the trunk room left side trim.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Specifications

    S

    Kia Cadenza YG 2016-2021 Service Manual: Cluster ionizer Description and Operation

    Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.