| Inspection |
| 1. |
Open the fuel filler door and remove the fuel filler door release actuator (A) after loosening the mounting bolts.
|
| 2. |
Remove the trunk room left side trim.
(Refer to Body - "Interior Trim") |
| 3. |
Disconnect the release actuator connector (A).
|
| 4. |
Check for continuity between terminal No.1 and No.2.
If there is no continuity, replace the fuel filler door opener. |
Component Location 1. Fuel filler door open switch2. Fuel filler door release actuator
Inspection 1. Open the junction box fuse cover. 2. Insert the hand to the junction box fuse cover hole and remove the crash pad side switch assembly (A) by pushing it.
Circuit Diagram SVM System Input/Output 1. Camera input ItemSpecificationLens angle of view190 degreesAngle of viewHorizontal186 degreesVertical135 degreesFunctionProvides the original image of the wide angle image (no additional function)Application locationSame camera applied to the front, rear, left and right 2.
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.