| Specification |
| Item | Specification |
| Control type | N/H (Normal High) |
| Control pressure kpa (kgf/cm², psi) | 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42) |
| Current value (mA) | 50 ~ 850 |
| Coil resistance(Ω) | 5.1 ± 0.3 |
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A).
Component Location 1. Line pressure control solenoid valve (LINE_VFS)
Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2. Check the condenser connections for leakage, and repair or replace it, if required.
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation. 3. If the problem is corrected, replace the blower motor.