| Specifications |
| Items | Specifications | |
| Rated voltage | DC +5V | |
| Load | Max. 1mA (When head lamp lighting) | |
| Illuminations | Tail lamp | ON : 0.52 ± 0.03 (V) |
| OFF : 1.58 ± 0.05 (V) | ||
| Head lamp | ON : 0.52 ± 0.03 (V) | |
| OFF : 1.58 ± 0.05 (V) | ||
Component Location 1. Auto light sensor2. Head lamps3. Lighting switch (Auto)4. Tail lamps5. IPM (Intelligent intergrated Platform Module)
Instructions When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves. 2. It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.