| Removal |
| 1. |
Disconnect the negative (-) battery terminal. |
| 2. |
Remove the floor console upper cover.
(Refer to Body - "Floor Console Assembly") |
| 3. |
Disconnect the console upper cover connector (A).
|
| 4. |
Remove the cup holder assembly (A) after loosening the mounting screws.
|
| 5. |
Remove the SVM switch (A) after loosening the mounting screws.
|
| Installation |
| 1. |
Install the SVM switch and cup holder assembly. |
| 2. |
Install the console upper cover. |
Removal Front Pantoscopic Camera 1. Disconnect the negative (-) battery terminal. 2. Remove the front bumper cover. (Refer to Body - "Front Bumper Cover") 3.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.