| Description |
| 1. |
Heater unit includes mode control actuator and temperature control actuator. |
| 2. |
Temperature control actuator is located at the heater unit.
It regulates the temperature by the procedure as follows. Signal from
control unit adjusts position of temperature door by operating
temperature switch and then temperature will be regulated by the
hot/cold air ratio decided by position of temperature door |
Component Location
Inspection 1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7.
Troubleshooting Examples of False-Alarm Occurrence from system characteristics (It’s not a problem) – Characteristics of EM Wave : EM Waves are reflected against all material and especially metal very well. Reflections of EM Waves are varies with the shape of object.
Component Location Components 1. Duct Seal2. Duct Case3. Inlet Door4. Intake Actuator5. Inlet Duct Case (A)6. Climate control air filter7. Cluster Ionizer8. Climate control air filter Cover9. Blower Upper Case10. Blower Lower Case11. FET12. Resistor13.