| Description |
| 1. |
Heater unit includes mode control actuator and temperature control actuator. |
| 2. |
Temperature control actuator is located at the heater unit.
It regulates the temperature by the procedure as follows. Signal from
control unit adjusts position of temperature door by operating
temperature switch and then temperature will be regulated by the
hot/cold air ratio decided by position of temperature door |
Component Location
Inspection 1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7.
Description System Operation Typically, lane departure warning is activated at a speed over 70 KPH, but suppressed in case of unintentional lane departure when driver do not operate turn signal. System Operation Conditions 1. User Conditions (1) When unintended lane departure is occured, warnings are generated.