| 1. |
Mode
| (1) |
Configuration State
|
•
|
All sensors should be in the Low Line state. |
|
•
|
In High Line configuration, sensor transmissions occur every 1 minute (nominal) and pressure is measured every 4 seconds. |
|
| (2) |
Normal Delayed Auto State
|
•
|
This is High Line specific and is used for all HMC/KMC High Line applications. |
|
•
|
In this state, the sensor will transmit for approx. 12 minutes before automatically entering storage state. |
|
| (3) |
Storage Auto State
|
•
|
This state is a Low quiescent current state. |
| b. |
The sensor does not measure pressure / temperature / battery level. |
| c. |
The sensor will not transmit, unless requested to do so by the initiate command. |
|
|
| (4) |
Alert State
|
•
|
The sensor automatically enters this state if the measured temperature exceeds 110°C and over temperature shutdown is likely. |
|
•
|
In this state, pressure is measured every 4 seconds and RF data transmitted every 4 seconds. |
|
•
|
The state lasts for 1 minute if it is pressure triggered. |
|
| (5) |
KDS state
|
•
|
MP : Parking Mode: no motion for 15 minutes |
|
•
|
MFB : First Block Mode: change from Parking to MFB when sensor sees over 4G. Stays in MFB for about 10 min. |
|
•
|
MD : Driving Mode: in MFB, movement over 4G for 10 minutes will enter Driving Mode. |
|
|