| Replacement |
| 1. |
Discharge refrigerant from refrigeration system. |
| 2. |
Replace faulty tube or hose.
|
| 3. |
Tighten joint of bolt or nut to specified torque.
|
| 4. |
Evacuate air in refrigeration system and charge system with refrigerant.
|
| 5. |
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant. |
| 6. |
Inspect A/C operation. |
Component Location
Components 1. Screw2. Blot3. Limiter Assembly4. Retainer Ring5. Pulley6. Compressor Assembly
Inspection 1. Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals. 2. Inspect the voltage value whether it is sufficient to be regular value or not. Voltage = 0.00878835 * Pressure + 0.37081095 [PSIA] 3.
Inspection Self diagnosis 1. Self-diagnosis process 2. How to read self-diagnostic code. After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.