| Replacement |
| 1. |
Discharge refrigerant from refrigeration system. |
| 2. |
Replace faulty tube or hose.
|
| 3. |
Tighten joint of bolt or nut to specified torque.
|
| 4. |
Evacuate air in refrigeration system and charge system with refrigerant.
|
| 5. |
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant. |
| 6. |
Inspect A/C operation. |
Component Location
Components 1. Screw2. Blot3. Limiter Assembly4. Retainer Ring5. Pulley6. Compressor Assembly
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal23Auto defog sensor OPEN24Auto defog sensor SHORT43Defog door potentiometer OPEN/SHORT44Defog door potentiometer * Diagnostic procedure refer to DTC code.
Inspection Self diagnosis 1. Self-diagnosis process 2. How to read self-diagnostic code. After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.