| Specification |
| Item | Specification | |
| Model | RADIO/CD/MP3 (PA30B) | |
| Power supply | DC 14.4V | |
| Rated output | Max 43W x 4 | |
| Impedanec (Ω) | 4 ohm x 4 | |
| Antenna | 80PF 75Ω | |
| Tuning type | PLL synthesized type | |
| Other | Internal amplifier | |
| Frequency range / Channel space | FM | 87.5 ~ 107.9 MHz/200 KHz |
| AM | 530 ~ 1710 KHz/10 KHz | |
| Item | PA30B | ||
| Input power (W or V) | Front | MAX 50W | |
| Rear | MAX 50W | ||
| Front tweeter | MAX 40W | ||
| Impedance (Ω) | Front | 4 ± 0.6 | |
| Rear | 2.0 ± 0.3 | ||
| Front tweeter | 3.4 ± 0.5 | ||
| Number of speaker | 6 | ||
Component Location 1. Audio unit2. Front tweeter speaker3. Glass antenna amplifier (Diversity type)4. Front door speaker5. Rear speaker6. Antenna feeder cable7.
Refrigerant System Service Basics Refrigerant Recovery Use only service equipment that is U.L-listed and is certified to meet the requirements of SAE J2210 to remove HFC-134a(R-134a) from the air conditioning system. – Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or th
Replacement 1. Remove the condenser, and then remove the bottom cap (B) with L wrench (A) from the condenser. Tightening torque : 9.8~14.7N.m (1.0~1.5kgf.m, 7.2~10.8 lb-ft) 2. Remove the desiccant (A) from condenser using a long nose plier.