Kia Cadenza YG: Heating,Ventilation, Air Conditioning / Specifications

Specification
Air Conditioner
Item
Specification
Compressor
Type
6VSX16
Oil type & Capacity
PAG OIL 100±10
Pulley type
6PK-TYPE
Displacement
160cc/rev
Condenser
Heat rejection
14,400 ±5% kcal/hr
A/C Pressure transducer
The method to measure the pressure
Voltage= 0.00878835 * Pressure (psig) + 0.37081095
Expansion valve
Type
Block type
Refrigerant
Type
R-134a
Capacity [oz.(g)]
22.9 ± 0.88 oz. (650±25g)

Blower Unit
Item
Specification
Fresh and recirculation
Operating method
Actuator
Blower
Type
Sirocco
Speed step
Auto + 8 speed (Automatic), 1~4speed (Manual)
Speed control
Power mosfet (Auto) , Resistor (Manual)
Air filter
Type
Particle filter

Heater And Evaporator Unit
Item
Specification
Heater
Type
Pin & Tube type
Heating capacity
4,850 - 5% kcal/hr
Mode operating method
Actuator
Temperature operating method
Actuator
Evaporator
Temperature control type
Evaporator temperature sensor
A/C ON/OFF [°C(°F)]
ON : 3.0 ± 0.5 (39.4 ± 32.9), OFF: 0 ± 0.3 (32.0 ± 32.9)

    Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Repair procedures

    Diagnosis With GDS 1. BSD system defects can be quickly diagnosed with the GDS. GDS operates actuator quickly to monitor, input/output value and self diagnosis. 2. Connect the cable of GDS to the data link connector in driver side crash pad lower panel, turn the power on GDS.

    Kia Cadenza YG 2016-2021 Service Manual: Cluster ionizer Description and Operation

    Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.

    Categories

     
    Copyright © 2025 www.kcadenzavg.com - 0.0186