| Specification |
| Item | Specification | |
| Compressor | Type | 6VSX16 |
| Oil type & Capacity | PAG OIL 100±10 | |
| Pulley type | 6PK-TYPE | |
| Displacement | 160cc/rev | |
| Condenser | Heat rejection | 14,400 ±5% kcal/hr |
| A/C Pressure transducer | The method to measure the pressure | Voltage= 0.00878835 * Pressure (psig) + 0.37081095 |
| Expansion valve | Type | Block type |
| Refrigerant | Type | R-134a |
| Capacity [oz.(g)] | 22.9 ± 0.88 oz. (650±25g) | |
| Item | Specification | |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco |
| Speed step | Auto + 8 speed (Automatic), 1~4speed (Manual) | |
| Speed control | Power mosfet (Auto) , Resistor (Manual) | |
| Air filter | Type | Particle filter |
| Item | Specification | |
| Heater | Type | Pin & Tube type |
| Heating capacity | 4,850 - 5% kcal/hr | |
| Mode operating method | Actuator | |
| Temperature operating method | Actuator | |
| Evaporator | Temperature control type | Evaporator temperature sensor |
| A/C ON/OFF [°C(°F)] | ON : 3.0 ± 0.5 (39.4 ± 32.9), OFF: 0 ± 0.3 (32.0 ± 32.9) | |
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Description System Operation Typically, lane departure warning is activated at a speed over 70 KPH, but suppressed in case of unintentional lane departure when driver do not operate turn signal. System Operation Conditions 1. User Conditions (1) When unintended lane departure is occured, warnings are generated.
Removal 1. If the compressor is marginally operable, run the engine at idle speed, and let the air conditioning work for a few minutes, then shut the engine off. 2. Disconnect the negative cable from the battery. 3. Recover the refrigerant with a recovery/charging station.