Kia Cadenza: Heating,Ventilation, Air Conditioning / Specifications
Air Conditioner
Item
| Specification
|
Compressor
| Type
| 6VSX16
|
Oil type & Capacity
| PAG OIL 100±10
|
Pulley type
| 6PK-TYPE
|
Displacement
| 160cc/rev
|
Condenser
| Heat rejection
| 14,400 ±5% kcal/hr
|
A/C Pressure transducer
| The method to measure the pressure
| Voltage= 0.00878835 * Pressure (psig) + 0.37081095
|
Expansion valve
| Type
| Block type
|
Refrigerant
| Type
| R-134a
|
Capacity [oz.(g)]
| 22.9 ± 0.88 oz. (650±25g)
|
Blower Unit
Item
| Specification
|
Fresh and recirculation
| Operating method
| Actuator
|
Blower
| Type
| Sirocco
|
Speed step
| Auto + 8 speed (Automatic), 1~4speed (Manual)
|
Speed control
| Power mosfet (Auto) , Resistor (Manual)
|
Air filter
| Type
| Particle filter
|
Heater And Evaporator Unit
Item
| Specification
|
Heater
| Type
| Pin & Tube type
|
Heating capacity
| 4,850 - 5% kcal/hr
|
Mode operating method
| Actuator
|
Temperature operating method
| Actuator
|
Evaporator
| Temperature control type
| Evaporator temperature sensor
|
A/C ON/OFF [°C(°F)]
| ON : 3.0 ± 0.5 (39.4 ± 32.9), OFF: 0 ± 0.3 (32.0 ± 32.9)
|
Troubleshooting
Problem Symptoms Table
Before replacing or repairing air conditioning components,
first determine if the malfunction is due to the refrigerant charge, air
flow or compressor. ...
Other information:
Specification
ItemSpecification Primary Coil Resistance (Ω)0.62 ± 10% [20°C (68°F)]Secondary Coil Resistance (kΩ)7.0 ± 15% [20°C (68°F)]
...
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the LDWS unit cover (A).
3.
Remove the LDWS unit connector (A).
4.
Remove the LDWS unit after widening the mounting clips.
Installation
1.
Install the LDWS unit.
2.
Install the LDWS unit cover.
3.
Check L ...