| Specification |
| Item | Specification | |
| Compressor | Type | 6VSX16 |
| Oil type & Capacity | PAG OIL 100±10 | |
| Pulley type | 6PK-TYPE | |
| Displacement | 160cc/rev | |
| Condenser | Heat rejection | 14,400 ±5% kcal/hr |
| A/C Pressure transducer | The method to measure the pressure | Voltage= 0.00878835 * Pressure (psig) + 0.37081095 |
| Expansion valve | Type | Block type |
| Refrigerant | Type | R-134a |
| Capacity [oz.(g)] | 22.9 ± 0.88 oz. (650±25g) | |
| Item | Specification | |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco |
| Speed step | Auto + 8 speed (Automatic), 1~4speed (Manual) | |
| Speed control | Power mosfet (Auto) , Resistor (Manual) | |
| Air filter | Type | Particle filter |
| Item | Specification | |
| Heater | Type | Pin & Tube type |
| Heating capacity | 4,850 - 5% kcal/hr | |
| Mode operating method | Actuator | |
| Temperature operating method | Actuator | |
| Evaporator | Temperature control type | Evaporator temperature sensor |
| A/C ON/OFF [°C(°F)] | ON : 3.0 ± 0.5 (39.4 ± 32.9), OFF: 0 ± 0.3 (32.0 ± 32.9) | |
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Inspection 1. Ignition "OFF" 2. Disconnect ambient temperature sensor. 3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature. 1. Sensor Ground2.
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation. 3. If the problem is corrected, replace the blower motor.