| Specification |
| Item | Specification | |
| Compressor | Type | 6VSX16 |
| Oil type & Capacity | PAG OIL 100±10 | |
| Pulley type | 6PK-TYPE | |
| Displacement | 160cc/rev | |
| Condenser | Heat rejection | 14,400 ±5% kcal/hr |
| A/C Pressure transducer | The method to measure the pressure | Voltage= 0.00878835 * Pressure (psig) + 0.37081095 |
| Expansion valve | Type | Block type |
| Refrigerant | Type | R-134a |
| Capacity [oz.(g)] | 22.9 ± 0.88 oz. (650±25g) | |
| Item | Specification | |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco |
| Speed step | Auto + 8 speed (Automatic), 1~4speed (Manual) | |
| Speed control | Power mosfet (Auto) , Resistor (Manual) | |
| Air filter | Type | Particle filter |
| Item | Specification | |
| Heater | Type | Pin & Tube type |
| Heating capacity | 4,850 - 5% kcal/hr | |
| Mode operating method | Actuator | |
| Temperature operating method | Actuator | |
| Evaporator | Temperature control type | Evaporator temperature sensor |
| A/C ON/OFF [°C(°F)] | ON : 3.0 ± 0.5 (39.4 ± 32.9), OFF: 0 ± 0.3 (32.0 ± 32.9) | |
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Inspection 1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7. Verify that the temperature control actuator operates to the cool position when connecting in the rev
Replacement 1. Disconnect the damper (B) from the glove box (A) and then remove the glove box lift (C). 2. Remove the filter cover (A) with pushing the knob. 3. Replace the air filter (B), install it after making sure of the direction of air filter.