| Specification |
| Item | Specification |
| Control type | N/L (Normal Low) |
| Control pressure kpa (kgf/cm², psi) | "9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54)" |
| Current value (mA) | 50 ~ 850 |
| Coil resistance(Ω) | 5.1 ± 0.3 |
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A).
Component Location 1. Torque Converter Control Solenoid Valve (T/CON_VFS)
Inspection 1. Ignition "ON" 2. Using the scan tool. 3. Emit intensive light toward photo sensor using a lamp, and check the output voltage change. 4. The voltage will rise with higher intensive light and reduce with lower intensive light.
Inspection 1. Measure terminal - to - terminal resistance of blower resistor. 2. If measure resistance isnot within specification, the blower resistor must be replaced. Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower cover (A) and then disconnect the connector (B).