| Troubleshooting |
| Problem Symptoms Table |
| Standard : |
| Symptom | Suspect Area |
| No blower operation | 1. Blower fuse |
| 2. Blower relay | |
| 3. Blower motor | |
| 4. Power mosfet | |
| 5. Blower speed control switch | |
| 6. Wire harness | |
| No air temperature control | 1. Engine coolant capacity |
| 2. Heater control assembly | |
| No compressor operation | 1. Refrigerant capacity |
| 2. A/C Fuse | |
| 3. Compressor | |
| 4. A/C pressure transducer | |
| 5. A/C switch | |
| 6. Evaporator temperature sensor | |
| 7. Wire harness | |
| No cool comes out | 1. Refrigerant capacity |
| 2. Refrigerant pressure | |
| 3. Drive belt. | |
| 4. Compressor | |
| 5. A/C pressure transducer | |
| 6. Evaporator temperature sensor. | |
| 7. A/C switch. | |
| 8. Heater control assembly | |
| 9. Wire harness | |
| Insufficient cooling | 1. Refrigerant capacity |
| 2. Drive belt | |
| 3. Compressor | |
| 4. Condenser | |
| 5. Expansion valve | |
| 6. Evaporator | |
| 7. Refrigerant lines | |
| 8. A/C pressure transducer | |
| 9. Heater control assembly | |
| No engine idle-up when A/C switch ON | 1. Engine ECM |
| 2. Wire harness | |
| No air inlet control | 1. Heater control assembly |
| 2. Intake actuator | |
| No mode control | 1. Heater control assembly |
| 2. Mode actuator | |
| No cooling fan operation | 1. Cooling fan fuse |
| 2. Fan motor | |
| 3. Engine ECM | |
| 4. Wire harness |
Specification Air Conditioner ItemSpecificationCompressorType6VSX16Oil type & CapacityPAG OIL 100±10Pulley type6PK-TYPEDisplacement160cc/revCondenserHeat rejection14,400 ±5% kcal/hrA/C Pressure transducerThe method to measure the pressureVoltage= 0.
Special Service Tools Tool (Number and name)IllustrationUse09977-3R000Disc & hub assembly bolt removerRemoval and installation of limiter assembly.
Description Back view camera will activate when the backup light is ON with the ignition switch ON and the shift lever in the R position. This system is a supplemental system that shows behind the vehicle through the ECM (Reverse Display Room Mirror) mirror or AVN head unit while backing-up.
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.