Kia Cadenza YG: Blower / Blower Unit Repair procedures

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater and blower unit.(Refer to HA group – heater unit).
3.
Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.

   
Make sure that there is no air leaking out of the blower and duct joints.
4.
Installation is the reverse order of removal.

    Component Location Components 1. Duct Seal2. Duct Case3. Inlet Door4. Intake Actuator5. Inlet Duct Case (A)6. Climate control air filter7. Cluster Ionizer8.

    Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Auto Head lamp leveling Unit Description and Operation

    Description According to driving environment and loading state of vehicle, head lamp lighting direction is changed to keep the driver''s visibility range and to protect the driver''s vision from glare, aiming at safety driving. Sensor mounting on the rear center arm drives the actuator mounting on the head lamp since sensing the input

    Kia Cadenza YG 2016-2021 Service Manual: Blower Resistor Repair procedures

    Inspection 1. Measure terminal - to - terminal resistance of blower resistor. 2. If measure resistance isnot within specification, the blower resistor must be replaced. Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower cover (A) and then disconnect the connector (B).