| Removal |
| 1. |
Remove the fuel pump.
(Refer to Fuel Delivery System - “Fuel Pump”) |
| 2. |
Disconnect the electric pump wiring connector (A) and the fuel sender connector (B).
|
| 3. |
Remove the cushion pipe fixing clip (A), and then separate the head assembly (B) from reservoir cup.
|
| 4. |
Remove the return nozzle (B) after releasing the fixing hook (A).
|
| 5. |
Remove the reservoir-cup after releasing the fixing hooks (A).
|
| 6. |
Remove the pre-filter (B) after releasing the fixing hooks (A).
|
| 7. |
Separate the electric pump motor (A) and regulator (B) from the fuel filter (C).
|
| Installation |
| 1. |
Install in the reverse order of removal. |
Inspection [Fuel pump] 1. Turn the ignition switch OFF, and then remove battery (-) cable. 2. Remove the fuel pump assembly. 3. Check that motor operates properly when applying battery voltage to terminals 2 and 4 of fuel pump connector (A).
Removal 1. Remove the fuel pump. (Refer to Fuel Delivery System - “Fuel Pump”) 2. Disconnect the electric pump wiring connector (A) and the fuel sender connector (B).
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.
Replacement 1. Disconnect the damper (B) from the glove box (A) and then remove the glove box lift (C). 2. Remove the filter cover (A) with pushing the knob. 3. Replace the air filter (B), install it after making sure of the direction of air filter.