Kia Cadenza YG: Cooling System / Cooling Fan Description and Operation

Description
[Air conditioning type]
The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
[Cooling fan operation conditions]
A/C switch
A/C pressure
[kgf/cm² G (psi G)]
Vehicle speed
[km/h (mph)]
Coolant temperature
[°C (°F)]
Cooling fan speed
OFF

V < 45 (28)
100 ~ 105 (212 ~ 221)
LOW
105 (221) or above
HIGH
45 (28) ≤ V < 80 (49.7)
100 ~ 105 (212 ~ 221)
LOW
105 (221) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
ON
P < 6 (85.3)
All
105 (221) or above
HIGH
6 (85.3) ≤ P < 12 (170.7)
V < 45 (28)
60 ~ 100 (140 ~ 212)
LOW
100 (212) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
12 (170.7) ≤ P < 15.5 (120.5)
V < 45 (28)
-30 ~ 95 (-22 ~ 203)
LOW
95 (203) or above
HIGH
45 (28) ≤ V < 80 (49.7)
95 ~ 100 (203 ~ 212)
LOW
100 (212) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH
15.5 (120.5) ≤ P
All
-30 (-22) or above
HIGH

[Non-Air conditioning type]
The cooling fan operates in 1 stages (HIGH). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
[Cooling fan operation conditions]
A/C switch
A/C pressure
[kgf/cm² G (psi G)]
Vehicle speed
[km/h (mph)]
Coolant temperature
[°C (°F)]
Cooling fan speed
OFF

V < 45 (28)
100 ~ 105 (212 ~ 221) or above
HIGH
45 (28) ≤ V < 80 (49.7)
100 ~ 105 (212 ~ 221) or above
HIGH
80 (49.7) ≤ V
105 (221) or above
HIGH

    Components 1. Cooling fan2. Fan motor3. Fan shroud4. Resistor

    Specifications ItemSpecificationFan typePULLERFan speed controlResistor (HI-LOW-OFF)Air flow rate [㎥/h (yd³/h)]2,650 (3,466) -10% min.Fan speed (rpm)1,890 ±10%Current (A)19.

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Cluster ionizer Description and Operation

    Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.

    Kia Cadenza YG 2016-2021 Service Manual: Blower Unit Components and Components Location

    Component Location Components 1. Duct Seal2. Duct Case3. Inlet Door4. Intake Actuator5. Inlet Duct Case (A)6. Climate control air filter7. Cluster Ionizer8. Climate control air filter Cover9. Blower Upper Case10. Blower Lower Case11. FET12. Resistor13.

    Categories

     
    Copyright © 2026 www.kcadenzavg.com - 0.021