| Specifications |
| Item | Specification |
| Fan type | PULLER |
| Fan speed control | Resistor (HI-LOW-OFF) |
| Air flow rate [㎥/h (yd³/h)] | 2,650 (3,466) -10% min. |
| Fan speed (rpm) | 1,890 ±10% |
| Current (A) | 19.0 +10% max. |
Description [Air conditioning type] The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
Circuit Diagram
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.
Inspection 1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7. Verify that the temperature control actuator operates to the cool position when connecting in the rev