| Specifications |
| Item | Specification |
| Fan type | PULLER |
| Fan speed control | Resistor (HI-LOW-OFF) |
| Air flow rate [㎥/h (yd³/h)] | 2,650 (3,466) -10% min. |
| Fan speed (rpm) | 1,890 ±10% |
| Current (A) | 19.0 +10% max. |
Description [Air conditioning type] The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.
Circuit Diagram
Removal 1. Disconnect the negative (-) battery terminal. 2. Using a screw driver or remover, remove the center fascia lower panel (A). 3. Remove the in-car hose (A) and disconnect the connectors (B) from the heater & A/C control unit. 4.
Inspection 1. Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals. 2. Inspect the voltage value whether it is sufficient to be regular value or not. Voltage = 0.00878835 * Pressure + 0.37081095 [PSIA] 3.