Kia Cadenza YG: Cooling System / Cooling Fan Specifications

Specifications
Item
Specification
Fan type
PULLER
Fan speed control
Resistor (HI-LOW-OFF)
Air flow rate [㎥/h (yd³/h)]
2,650 (3,466) -10% min.
Fan speed (rpm)
1,890 ±10%
Current (A)
19.0 +10% max.

    Description [Air conditioning type] The cooling fan operates in 2 stages (HIGH/LOW). The engine control module (ECM) controls the cooling fan according to the coolant temperature, vehicle speed and A/C operation.

    Circuit Diagram

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Repair procedures

    Inspection Tolerance Calibration Tolerance calibration compensates for the error margins of surround view video that occur due to the installation tolerance when the four cameras that comprise the SVM system are installed. You must carry out tolerance calibration if you do any of the following.

    Kia Cadenza YG 2016-2021 Service Manual: Surround View Monitoring Switch Repair procedures

    Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the floor console upper cover. (Refer to Body - "Floor Console Assembly") 3. Disconnect the console upper cover connector (A). 4. Remove the cup holder assembly (A) after loosening the mounting screws.

    Categories

     
    Copyright © 2026 www.kcadenzavg.com - 0.0228