| Circuit Diagram |

Specifications ItemSpecificationFan typePULLERFan speed controlResistor (HI-LOW-OFF)Air flow rate [㎥/h (yd³/h)]2,650 (3,466) -10% min.Fan speed (rpm)1,890 ±10%Current (A)19.
Removal and Installaton Cooling Fan Assembly 1. Disconnect the battery negative terminal. 2. Remove the air duct (A). 3. 3. Loosen the upper hose fixing bolt (A), and disconnect the fan motor connector (B).
Inspection 1. Ignition "OFF". 2. Disconnect evaporator temperature sensor. 3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor. Specification Evaporator coretemperature [°C(°F)]Resistance[KΩ]Voltage[V]-20(-4)70.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.