| Description |
Component Location 1. Windshield deicer relay (Built-in engine room relay box)2. Windshield deicer switch (Rear glass defogger switch)3. Windshield deicer4.
Inspection 1. Remove the cowl top cover. (Refer to the wiper) 2. Disconnect the windshield deicer connector (A) from the wiper motor linkage. 3.
Replacement 1. Remove the condenser, and then remove the bottom cap (B) with L wrench (A) from the condenser. Tightening torque : 9.8~14.7N.m (1.0~1.5kgf.m, 7.2~10.8 lb-ft) 2. Remove the desiccant (A) from condenser using a long nose plier.
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.