| Inspection |
| 1. |
Remove the cowl top cover. (Refer to the wiper) |
| 2. |
Disconnect the windshield deicer connector (A) from the wiper motor linkage.
|
| 3. |
Check for continuity between the terminals of deicer lines.
|
| 4. |
Turn the ignition switch ON and the windshield deicer switch
ON, then measure the voltage between the terminals of harness side
deicer connector.
|
Description Windshield deicer system prevent windshield wiper from freezing in the winter season. It consists of deicer in the lower part of windshield, switch and relay.
Inspection 1. The windshield deicer switch inputs can be checked using the GDS. 2. To check the input value of windshield deicer switch, select option "IPM".
Specification Air Conditioner ItemSpecificationCompressorType6VSX16Oil type & CapacityPAG OIL 100±10Pulley type6PK-TYPEDisplacement160cc/revCondenserHeat rejection14,400 ±5% kcal/hrA/C Pressure transducerThe method to measure the pressureVoltage= 0.
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit.(Refer to HA group – heater unit). 3. Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws. Make sure that there is no air leaking out of the blower and duct joints.