| Circuit Diagram |

Specifications ▷ Type: Hall effect sensor Operation condition [°C(°F)]((-)40~150)) -40~302Air gap(mm)in.(0.8~1.25) 0.032~0.049Output voltageHigh1.
Signal Waveform Fig 1) Input/Output speed sensor at low speed Fig 2) Input/Output speed sensor at high speed
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation. 3. If the problem is corrected, replace the blower motor.