| Specifications |
| Item | Specification |
| Rating voltage | DC 12V |
| Operating voltage | DC 9V ~ 16V |
| Operating temperature | -30°C ~ +80°C |
| Maintaining temperature | -40°C ~ +85°C |
| Max, humid | 95% |
| Consumption current | MAX 700mA |
| Dark current | Below 2mA |
| Item | Specification |
| Rating voltage | 13.5V (Slide, Recline, Front height, Rear height) |
| Current | Slide : 8A |
| Recline : 8A | |
| Front height : 7.5A | |
| Rear height : 7.5A | |
| At worst current | Slide : 24A |
| Recline : 20A | |
| Front height : 25A | |
| Rear height : 27A |
| Mechanical System |
| Item | Specification |
| Type | Motor with hall IC |
| Duty ratio | 50 ± 15 |
| Total stroke | Slide : 240mm |
| Recline : 63° | |
| Front height : 32mm (Motor) | |
| Rear height : 52mm (Motor) | |
| Total pulse number | Slide : 899 |
| Recline : 1,136 | |
| Front height : 333 | |
| Rear height : 412 | |
| Moving speed (Terminal voltage : 13.5V) | Slide (Forward) : 17.9 mm /sec or more, Slide (Backward) : 20.2 mm /sec or more |
| Recline : 3.5 °/ sec | |
| Front height : 7 mm / sec or more | |
| Rear height : 7 mm / sec or more |
Component Location 1. Seat Memory Unit (IMS)2. IMS control switch3. IMS driver power seat control
Inspection Tolerance Calibration Tolerance calibration compensates for the error margins of surround view video that occur due to the installation tolerance when the four cameras that comprise the SVM system are installed. You must carry out tolerance calibration if you do any of the following.
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor. Use the table below to help you find the cause of the problem.