| Specification |
| Item | Specification | |
| Compressor | Type | 6VSX16 |
| Oil type & Capacity | PAG OIL 100±10 | |
| Pulley type | 6PK-TYPE | |
| Displacement | 160cc/rev | |
| Condenser | Heat rejection | 14,400 ±5% kcal/hr |
| A/C Pressure transducer | The method to measure the pressure | Voltage= 0.00878835 * Pressure (psig) + 0.37081095 |
| Expansion valve | Type | Block type |
| Refrigerant | Type | R-134a |
| Capacity [oz.(g)] | 22.9 ± 0.88 oz. (650±25g) | |
| Item | Specification | |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco |
| Speed step | Auto + 8 speed (Automatic), 1~4speed (Manual) | |
| Speed control | Power mosfet (Auto) , Resistor (Manual) | |
| Air filter | Type | Particle filter |
| Item | Specification | |
| Heater | Type | Pin & Tube type |
| Heating capacity | 4,850 - 5% kcal/hr | |
| Mode operating method | Actuator | |
| Temperature operating method | Actuator | |
| Evaporator | Temperature control type | Evaporator temperature sensor |
| A/C ON/OFF [°C(°F)] | ON : 3.0 ± 0.5 (39.4 ± 32.9), OFF: 0 ± 0.3 (32.0 ± 32.9) | |
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Removal 1. Remove the trunk trim in the trunk after removing the screws and clips. (Refer to Body - "Trunk") 2. Remove the camera holder (A) as shown arrow direction, and then remove the back view camera (B). Installation 1. Install the back view camera and camera holder.
Inspection 1. Ignition "OFF". 2. Disconnect evaporator temperature sensor. 3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor. Specification Evaporator coretemperature [°C(°F)]Resistance[KΩ]Voltage[V]-20(-4)70.