| Inspection |
| 1. |
Ignition "OFF” |
| 2. |
Disconnect the connector of mode control actuator. |
| 3. |
Verify that the mode control actuator operates to the defrost
mode when connecting 12V to the terminal 3and grounding terminal 7. |
| 4. |
Verify that the mode control actuator operates to the vent mode when connecting in the reverse.
|
| 5. |
Check the voltage between terminals 4 and 5.
Specification
It will feedback current position of actuator to controls. |
| 6. |
If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation. |
| 7. |
If the problem is corrected, replace the mode control actuator. |
| Replacement |
| 1. |
Disconnect the negative (-) battery terminal. |
| 2. |
Remove the crash pad left side cover (A).
|
| 3. |
Remove the console side cover [LH].
(Refer to BD group – "Console") |
| 4. |
Remove the crash pad lower cover (A) by loosening the mounting screws.
|
| 5. |
Disconnect the diagnosis connector (A) and then remove the crash pad lower cover.
|
| 6. |
Remove the left shower duct (A).
|
| 7. |
Remove the BCM(A) by loosening the mounting bolt and nut.
|
| 8. |
Disconnect the mode control actuator connector (A). |
| 9. |
Loosen the mounting screw and then remove the mode control actuator (B).
|
| 10. |
Installation is the reverse order of removal. |
Description The mode control actuator is located at the heater unit. It adjusts position of mode door by operating mode control actuator based on signal of A/C control unit.
Component Location
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal23Auto defog sensor OPEN24Auto defog sensor SHORT43Defog door potentiometer OPEN/SHORT44Defog door potentiometer * Diagnostic procedure refer to DTC code.
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.