Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake
manifold. It is a solenoid valve and is open when the ECM grounds the
valve control line. When the passage is open (PCSV ON), fuel vapor
stored in the canister is transferred to the intake manifold.
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance between the injector terminals 1 and 2.
4.
Check that the resistance is within t ...
Inspection
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Measure the output voltage of the MAPS at idle and IG ON.
ConditionOutput Voltage (V)IG ONApprox. 4.44VIdleApprox. 0.75V
Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2 ...