| Specifications |
| Items | Specifications | |
| Rated voltage | DC 12V | |
| Operating temperature range | -30°C ~ +80°C (-22 ~ +176°F) | |
| Rated load | Dimmer & passing switch | High : 0.2A (Relay load) Low : 0.2A (Relay load) Passing : 0.2A (Relay load) |
| Lighting switch / Auto lighting switch | Lighting : 0.2A (Relay load) | |
| Turn signal & lane change switch | 6.6 A | |
| Front & rear fog lamp switch | 0.2A (Relay load) | |
| Wiper & mist switch | Low, High : 4.5A (Motor load) Auto : 0.22 ± 0.05A (Relay load) Lock : Max. 28A (Motor load) | |
| Washer switch | 4A (Motor load) | |
| Variable intermittent volume switch | Max. 25mA | |
Component (1) 1. Steering column2. Lighting switch3. Wiper switch4. Screw5. Steering angle sensor6. Clock spring Component (2)
Inspection 1. Ignition "OFF". 2. Disconnect evaporator temperature sensor. 3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor. Specification Evaporator coretemperature [°C(°F)]Resistance[KΩ]Voltage[V]-20(-4)70.
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit.(Refer to HA group – heater unit). 3. Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws. Make sure that there is no air leaking out of the blower and duct joints.