| Specification |
| Item | Specification |
| Control type | N/H (Normal High) |
| "Control pressure kpa (kgf/cm², psi)" | "500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)" |
| Current value (mA) | 50 ~ 850 |
| Coil resistance(Ω) | 5.1 ± 0.3 |
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A).
Component Location 1. Underdrive brake control solenoid valve (UD/B_VFS)
Description 1. The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor resistance will increase with lower temperature, and decrease with higher temperatures.
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. Specification FanMotor VoltageManualFirst speed3.8 ±0.5VSecond speed5.