Kia Cadenza YG: Cylinder Block / Water Jacket Seperator Repair procedures

Removal
1.
Remove the LH/RH cylinder head assembly and gasket.
(Refer to Cylinder Head Assembly - "Cylinder Head")
2.
Remove the water jacket seperators (A).

Installation
1.
Install the #1, #2 cylinder bore water jacket seperators (A).

   
Insert the seperator align with block inner side protrusion, and it must be located under the cylinder head installing surface.

2.
Install the LH/RH cylinder head assembly and gasket.
(Refer to Cylinder Head Assembly - "Cylinder Head")

    Components 1. Water jacket separator

    Components 1. Drive plate2. Adapter plate

    Other information:

    Kia Cadenza YG 2016-2021 Service Manual: Cluster ionizer Repair procedures

    Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.

    Kia Cadenza YG 2016-2021 Service Manual: Auto defoging actuator Repair procedures

    Inspection 1. Ignition "OFF”. 2. Disconnect the connector of auto defog control actuator. 3. Verify that the auto defog control actuator operates to the defrost ON mode when connecting 12V to the terminal 3 and grounding terminal 7. 4.