| Specification |
| Item | Specification |
| Control type | N/H (Normal High) |
| Control pressure kpa (kgf/cm², psi) | "500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)" |
| Current value (mA) | 50 ~ 850 |
| Coil resistance(Ω) | 5.1 ± 0.3 |
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A).
Component Location 1. 35R Clutch control solenoid valve (35R/C_VFS)
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.