Troubleshooting SymptomSuspect areaEngine will not start or stuggle to startVapor hose damaged or disconnectedEngine stuggle to startMalfunction of the Purge Control Solenoid ValveRough idle or engine stallsVapor hose damaged or disconnectedMalfunction of the PCV valveRough idleMalfunction of the Evaporative Emission Control SystemExcessive oil consumptionPositive crankcase ventilation line clogged
Schematic Diagram
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower panel. (Refer to Body - "Crash Pad") 3. Disconnect the 5P connector of the SMARTRA unit and then remove the SMARTRA unit (A) after loosening the bolt. Installation 1.