| Specification |
| A/F Ratio (λ) | Output Voltage(V) |
| RICH | Min. 0.8 |
| LEAN | Max. 0.1 |
| Item | Specification |
| Heater Resistance (Ω) | 3.3 ~ 4.1[20°C(68°F)] |
Description Heated Oxygen Sensor (HO2S) consists of the zirconium and the alumina and is installed on upstream and downstream of the Warm-up Catalytic Converter (WCC).
C
Teaching Procedures 1. Key Teaching Procedure Key teaching must be done after replacing a defective PCM(ECM) or when providing additional keys to the vehicle owner. The procedure starts with an PCM(ECM) request for vehicle specific data (PIN code: 6digits) from the tester.