| Replacement |
| 1. |
Discharge refrigerant from refrigeration system. |
| 2. |
Replace faulty tube or hose.
|
| 3. |
Tighten joint of bolt or nut to specified torque.
|
| 4. |
Evacuate air in refrigeration system and charge system with refrigerant.
|
| 5. |
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant. |
| 6. |
Inspect A/C operation. |
Component Location
Components 1. Screw2. Blot3. Limiter Assembly4. Retainer Ring5. Pulley6. Compressor Assembly
Description System Overview The System offers the following features: – Human / machine interface through a 1-stage button, for terminal switching and engine start. – Control of external relays for ACC / IGN1 / IGN2 terminal switching and STARTER, without use of mechanical ignition switch.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.