| Replacement |
| 1. |
Discharge refrigerant from refrigeration system. |
| 2. |
Replace faulty tube or hose.
|
| 3. |
Tighten joint of bolt or nut to specified torque.
|
| 4. |
Evacuate air in refrigeration system and charge system with refrigerant.
|
| 5. |
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant. |
| 6. |
Inspect A/C operation. |
Component Location
Components 1. Screw2. Blot3. Limiter Assembly4. Retainer Ring5. Pulley6. Compressor Assembly
Component Location 1. Start Stop Button(SSB)2. FOB key3. RF receiver4. Smart key unit5. Interior antenna 16. Interior antenna 2 7. Trunk antenna8. Bumper antenna9. Door handle & door antenna10. Trunk lid open switch11.
Inspection 1. Ignition "OFF". 2. Disconnect evaporator temperature sensor. 3. Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor. Specification Evaporator coretemperature [°C(°F)]Resistance[KΩ]Voltage[V]-20(-4)70.