| Replacement |
| 1. |
Discharge refrigerant from refrigeration system. |
| 2. |
Replace faulty tube or hose.
|
| 3. |
Tighten joint of bolt or nut to specified torque.
|
| 4. |
Evacuate air in refrigeration system and charge system with refrigerant.
|
| 5. |
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant. |
| 6. |
Inspect A/C operation. |
Component Location
Components 1. Screw2. Blot3. Limiter Assembly4. Retainer Ring5. Pulley6. Compressor Assembly
Inspection 1. Ignition "OFF" 2. Disconnect the connector of temperature control actuator. 3. Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 7. Verify that the temperature control actuator operates to the cool position when connecting in the rev
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. Specification FanMotor VoltageManualFirst speed3.8 ±0.5VSecond speed5.