| Specification |
| Item | Specification |
| Control type | ON/OFF |
| Current value (mA) | 5.0 |
| Coil resistance(Ω) | 10 ~ 11 |
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A).
Component Location 1. SS-B Solenoid Valve (ON/OFF)
Specification Air Conditioner ItemSpecificationCompressorType6VSX16Oil type & CapacityPAG OIL 100±10Pulley type6PK-TYPEDisplacement160cc/revCondenserHeat rejection14,400 ±5% kcal/hrA/C Pressure transducerThe method to measure the pressureVoltage= 0.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal50Cluster ionizer fault * Diagnostic procedure refer to DTC code. Replacement 1. Disconnect the negative (-) battery terminal.