| Specification |
| Item | Specification |
| Control type | N/L (Normal Low) |
| Control pressure kpa (kgf/cm², psi) | "9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54)" |
| Current value (mA) | 50 ~ 850 |
| Coil resistance(Ω) | 5.1 ± 0.3 |
Inspection 1. Turn ignition switch OFF. 2. Remove the battery and battery tray. (Refer to Engine Electrical System - "Battery") 3. Disconnect the solenoid valve connector (A).
Component Location 1. Torque Converter Control Solenoid Valve (T/CON_VFS)
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.
Inspection 1. Ignition "OFF” 2. Disconnect the connector of mode control actuator. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7. 4. Verify that the mode control actuator operates to the vent mode when connecting in the reverse.