| Components |

| 1. Water pipe 2. Throttle body coolant hose & pipe | 3. Water temperature control assembly 4. O-ring |
Removal and Installation 1. Disconnect the over flow hose (A), and then remove the resorvior tank (B). Tightening torque: 3.9 ~ 5.9 N.m (0.4 ~ 0.
Removal and Installation • To avoid damage, unplug the wiring connectors carefully while holding the connector portion.
Inspection 1. Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch. DisplayFail description00Normal23Auto defog sensor OPEN24Auto defog sensor SHORT43Defog door potentiometer OPEN/SHORT44Defog door potentiometer * Diagnostic procedure refer to DTC code.
Inspection 1. Ignition "OFF". 2. Disconnect the intake actuator connector. 3. Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 7. 4. Verify that the intake actuator operates to the fresh position when connecting in the reverse.