| Removal |
| 1. |
Disconnect the negative (-) battery terminal. |
| 2. |
Remove the rear bumper.
(Refer to Body - "Rear Bumper") |
| 3. |
Remove the BSD unit (A) after loosening the mounting screws.
|
| Installation |
| 1. |
Install the BSD units to the rear bumper. |
| 2. |
Install the rear bumper. |
| 3. |
Connect the negative (-) battery terminal.
| |||||||||||||
Circuit Diagram
Description The used radar frequency of BSD is two, "North America region" and "Except North America region". If it replaces BSD unit, BSD unit has to perform the procedure of variant coding.
Inspection 1. Ignition "ON" 2. Using the scan tool. 3. Emit intensive light toward photo sensor using a lamp, and check the output voltage change. 4. The voltage will rise with higher intensive light and reduce with lower intensive light.
Description 1. The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner. 2. The function of cluster ion generator is controlling mold caused by stench of air conditioner and external inflow of air.